Lenze PLC Designer PLC Designer (R3-1) Manuel d'utilisateur Page 37

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 117
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 36
L-force | PLC Designer
Lenze Specific Functions
DMS 4.1 EN 03/2011 TD29 35
Function block L_SMC_ReadAxisError
Function library: L_SM3_DriveUtil.lib
This block serves to read the error code of a motion drive.
Inputs (VAR_IN)
Designator / Data type Info / Setting options
Axis / AXIS_REF Here, the axis structure for which the code is to be read is transferred.
xEnable / BOOL Activates the function.
Outputs (VAR_OUT)
Designator / Data type Value / Meaning
xValid / BOOL Request has been executed
xBusy / BOOL Request has been started
xError / BOOL Request executed with error
wErrorID / WORD Error number for this command to be executed, not the error number of the
drive
xAxisError / BOOL Drive has signalled an error
dwAxisErrorID / DWORD Read error number of the drive
Error messages
The following error messages have been stored:
Error number [hex] Description
SMC_RP_PARAM_UNKNOWN:=130 Unknown code
SMC_RP_REQUESTING_ERROR:=131 Read request has been aborted, e.g. because the drive did not
respond in the prescribed time.
For the meaning of the drive error numbers, please refer to the drive documentation.
Vue de la page 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 116 117

Commentaires sur ces manuels

Pas de commentaire