Industrial PC | Parameter setting & configuration
Web-based parameterisation with »WebConfig«
Requirements for working with the web-based parameterisation
46 L 2.5 EN - 01/2012
6. Select the User configured option.
Enter the IP address of the Industrial PC (default address: <192.168.5.99>).
Enter the subnet mask of the Engineering PC
(standard setting: <255.255.255.0>)
7. Close the individual dialog windows with OK or Close
The Properties of internet protocol (TCP/IP) dialog window
How to set the browser:
1. Open the browser at the Engineering PC
(This setting refers to the Microsoft Internet Explorer).
2. Select the Proxy settings dialog window
(ToolsInternet options ConnectionsSettingsAdvanced)
3. Position the cursor in the Exceptions field at the end of the entries available.
4. Enter the IP address of the Industrial PC:
<;172.31.217*> (example of the IP address of an Industrial PC, default address:
<192.168.5.99>)
5. Close the individual dialog windows with OK.