Lenze E94AYCIB Manuel d'utilisateur Page 29

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 78
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 28
Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17 29
6 Commissioning
6.1 Before initial switch-on
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6 Commissioning
During commissioning, system-related data such as motor parameters, operating parameters,
responses, and parameters for fieldbus communication are defined in the inverter. For Lenze
devices, this is done by means of codes.
The codes of the inverter and for communication are saved to the memory module in a non-volatile
data set.
In addition, there are codes for diagnosing and monitoring the stations.
Parameter reference
( 53)
6.1 Before initial switch-on
Note!
When parameterising the communication module, please note that the code number
depends on the slot of the standard device into which the communication module is
plugged.
The first two digits of the code number indicate the slot:
•C13nnn for slot MXI1
Parameters of the communication module for slot MXI1
( 55)
•C14nnn for slot MXI2
Parameters of the communication module for slot MXI2
( 63)
You also have to set the Parameters of the standard device that are relevant to
communication ( 53).
Stop!
Before switching on the Servo Drive 9400 and the communication module for the first
time, check the entire wiring for completeness, short circuit and earth fault.
Vue de la page 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 77 78

Commentaires sur ces manuels

Pas de commentaire