Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17 25
5 Installation
5.2 Electrical installation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.2.3 INTERBUS connection
The INTERBUS of the communication module is connected via the 9-pole Sub-D plug X206 (input)
and the 9-pole Sub-D socket X207 (output).
[5-5] INTERBUS terminals X206 (input) and X207 (output)
Assignment of the 9-pole Sub-D plug X206 (IN)
E94YCIB001C
Pin Name Input/output Description
1DO1 Input RS485: DO1 not inverted
2 DI1 Output RS485: DI1 not inverted
3GND Reference potential
4 Free not assigned
5Vcc5 Output 5 V DC
6 /DO1 Input RS485: DO1 inverted
7/DI1 Output RS485: DI1 inverted
8Vcc5 Output 5 V DC
9 Free not assigned