4 Technical data
General Data
EDK94AYCIB DE/EN/FR/ES/IT 1.0
36
H1_Daten−GHB Servo Drives 9400
4 Technical data
General Data
Range Values
Order designation E94AYCIB
Communication profile INTERBUS
Interfaces
l Input (IN): 9−pin Sub−D connector
l Input (OUT): 9−pin Sub−D socket
Communication medium RS485
Network topology Ring
Number of INTERBUS nodes
l 1 master
l 512 slaves
Baud rate 500 kBit/s or 2 MBit/s
(adjustable by means of DIP switches or codes)
Max. cable length
l 400 m at 500 kBit/s
l 150 m at 2 MBit/s
(between each of the individual INTERBUS nodes)
INTERBUS node Slave
Voltage supply External supply via the 2−pin plug connector
l "+": U = 24 V DC (+/− 10 %), Imax = 180 mA
l "−": reference potential for external voltage supply
Conformities, approvals CE
"Servo Drives 9400" hardware manual
Here you can find the ambient conditions and the electromagnetic
compatibility (EMC) specifications applying to the communication module.