2.2 AIF2_IO_AutomationInterface (node number 42)
9300 Servo PLC
System blocks
2−8
L
9300 Servo PLC EN 5.0
System variables
Variable Data type Signal type Address Display code Display
format
Note
AIF2_nInW1_a
Integer Analog
%IW42.0
AIF2_nInW2_a %IW42.1
AIF2_nInW3_a %IW42.2
AIF2_nInW4_a %IW42.3
AIF2_bInB0_b
Bool Binary
%IX42.0.0
... ...
AIF2_bInB15_b %IX42.0.15
AIF2_bInB16_b %IX42.1.0
... ...
AIF2_bInB31_b %IX42.1.15
AIF2_dnInD1_p Double integer Position %ID42.0
User data
The 4 first bytes of the received 8 bytes of user data are assigned to several variables of different data
types simultaneously. Thus the data can be evaluated in the PLC program as
binary information (1 bit)
quasi−analog value (16 bits)
angle information (32 bits)
according to the requirements.
Byte Variable (1 bit) Variable (16 bits) Variable (32 bits)
1, 2 AIF2_bInB0_b
...
AIF2_bInB15_b
AIF2_nInW1_a
AIF2_dnInD1_p
3, 4 AIF2_bInB16_b
...
AIF2_bInB31_b
AIF2_nInW2_a
5, 6
AIF2_nInW3_a
7, 8
AIF2_nInW4_a