Function
BOOL L_CanClose (wDrvNr)
By means of this function the CAN driver is deactivated.
· Transmission and reception tasks which are still available are cancelled when this function is
called.
L_CanClose
wDrvNr
Transfer parameters
Identifier Data type Possible settings Notes
wDrvNr Word 10 System bus
Return value
Data type Value Meaning Priority
Bool
0 Error while activating the driver
(incorrect driver number, or driver was not initialised.)
−
1 Driver has been deactivated.
Example
Calling the function in ST:
(* close CAN driver − returns g_bCanCloseState *)
g_bCanCloseState := L_CanClose(10)