Function block library LenzeElectricalShaft.lib
Special functions
2.1.4 Homing function (L_REF)
2−17
L
LenzeElectricalShaft.lib EN 1.2
2.1.4 Homing function (L_REF)
This FB is used to bring the drive shaft to a specific position.
L _ R E F
d n A c t P o s _ I n _ p
C T R L
b P o s L o a d _ b
b M a r k _ b
b O n _ b
n N I n _ a
d n P o s I n _ p
b R e f O k _ b
b R e f B u s y _ b
n N S e t _ a
b y H o m i n g M o d e
d n R e f O f f s e t
d n H o m i n g S p e e d
w T i T i m e H o m i n g
d n T a r g e t P o s
b A c t T P R e c e i v e d _ b
d n A c t T P L a s t S c a n _ p
T P / M P
C T R L
n N A c t _ v
d n A c t P o s
d n P o s O u t _ p
d n P o w D o w n A c t I n t e R e t a i n
Abb. 2−10 Homing function (L_REF)
VariableName
DataType SignalType VariableType Note
bActTPReceived_b Bool binary VAR_INPUT TouchProbe received
dnActTPLastScan_p Double Integer position VAR_INPUT Phase−angle difference between TouchProbe and start
of task
dnActPos_In_p Double Integer position VAR_INPUT Loading value for the current position
bPosLoad_b Bool binary VAR_INPUT FALSE−TRUE edge = phase−angle at input
dnActPosIn_p is loaded into REF−ACTPOS (start value)
bMark_b Bool binary VAR_INPUT Home position switch
bOn_b Bool binary VAR_INPUT TRUE = start homing
nNAct_v Integer velocity VAR_INPUT Actual speed, for calculating the actual position
(16384 º 15000 rpm)
nNIn_a Integer analog VAR_INPUT Speed setpoint in [%] of n
max
(C0011)
(C0011 º 100 % º 16384)
dnPosIn_p Double Integer position VAR_INPUT dnPosIn_p is switched through to dnPosOut_p after
homing
dnActPos Double Integer position VAR_OUTPUT Actual position of the calculated position profile
dnTargetPos Double Integer position VAR_OUTPUT Target position of the calculated position profile
bRefOk_b Bool binary VAR_OUTPUT TRUE = homing completed/reference point known
bRefBusy_b Bool binary VAR_OUTPUT TRUE = homing function active
nNSet_a Integer analog VAR_OUTPUT Speed setpoint for n−controller
dnPosOut_p Double Integer position VAR_OUTPUT Phase setpoint (contouring error for phase controller in
FB MCTRL)
dnPowDownActInte
Retain
Double Integer VAR_IN_OUT For Mode 21, to save the position after switching off
the supply power
byHomingMode Byte VAR CONSTANT RETAIN Setting for homing modes
dnRefOffset Double Integer VAR CONSTANT RETAIN Setting for homing offset (1 º 1 incr.)
dnHomingSpeed Double Integer VAR CONSTANT RETAIN Setting for homing speed
(286331153 º 16000 rpm)
wTiTimeHoming Word VAR CONSTANT RETAIN Setting for ramp time (100 º 1 s)