4 The Lenze automation system with PROFINET
12 Lenze · Controller-based Automation · PROFINET® Communication Manual · DMS 1.2 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4 The Lenze automation system with PROFINET
This chapter provides basic information about ...
the structure of the Lenze automation system using the PROFINET bus system;
the Lenze Engineering tools required for commissioning;
the interaction of the components.
We recommend using PROFINET for the following applications:
Equipment and extension of system parts that have already been automated with PROFINET
before.
Use of field devices that are not available for e.g. EtherCAT, CANopen or PROFIBUS.
The combination of PROFINET with EtherCAT is possible.
Tip!
Detailed information about PROFINET can be found on the website of the PROFIBUS &
PROFINET user organisation:
www.profibus.com
Note!
In the Lenze automation system, no PROFINET master functionality is supported. In a
PROFINET network, a Lenze Controller can only be driven as I/O device (slave), e.g. by
a Siemens SIMATIC S7 PLC.
In the Lenze automation system, Logic field devices can be exclusively operated via
PROFINET. Thus, as an I/O device, the Lenze Controller is a Logic field device.
The motion functionality is not supported when PROFINET is used. Always use
EtherCAT to connect inverters to be controlled via the central Motion functionality.
Mixed operation PROFINET with EtherCAT
( 32)