4 The Lenze automation system with PROFIBUS
4.1 Brief description of PROFIBUS
16
Lenze · Controller-based Automation · PROFIBUS® Communication Manual · DMS 4.3 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter setting
The PROFIBUS stations can be parameterised in different ways.
If field devices are used the parameters of which are completely written to an GSD/GSE file,
PROFIBUS can only be configured with the »PLC Designer«:
Import of the PROFIBUS slaves' GSD/GSE files into the »PLC Designer« project.
Set-up of the control configuration and creation of the PLC program
If PROFIBUS configuration is only possible via a PROFIdrive parameter channel, the
parameterisation can also be done using the »Engineer«/»EASY Starter« – depending on the device
type via the following interfaces:
•Ethernet
•CAN
Diagnostic interface
Note!
The "L-force Controller as gateway" function is not available in combination with
PROFIBUS. Therefore logging in with the »Engineer« via the controller as gateway is not
possible.