Drive PLC Developer Studio
Editors
7-35
l DDS EN 2.3
7.5.6 The FBD editor in online mode
In the FBD, breakpoints can only be set to networks. Where a breakpoint was set to a network, the
network number field is shown in blue. Processing stops in front of the network with the breakpoint,
and the network number field turns red. In single-stepping, the process jumps to every single
network.
Each variable is displayed with its current value.
Tip!
Only the first variable of the expression will be monitored (visible) if the input of a function block is
an expression.
Double-click the variable to open the write variable dialog.
The current value of the variable can then be changed.
No dialog appears for Boolean variables; these are toggled.
The new value is cyan and remains as-is.
Execution of menu command OnlineWWrite values sets all variables to the selected values
and displays them in black.