Lenze DDS Function library 9300 Servo Manuel d'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 29
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
Function block library Lenze9300Servo.lib
Special functions
2.1.1 Holding brake (L_BRK)
2−1
L
Lenze9300Servo.lib EN 1.1
2 Function blocks
2.1 Special functions
2.1.1 Holding brake (L_BRK)
This FB controls a holding brake. You can use it, for instance, for hoists and traversing drives, as well
as for active loads.
DCTRL_bCInh_b
MCTRL_nNAct_a
MCTRL_nNSet2_a
MCTRL_nMA ct_a
bSet_b
nNx_a
nSign_a
SIGN
nMSet
t 0
wActivationTime
t 0
wReleaseTime
L_BRK
bQSP_b
bOut_b
bMStore_b
bCInh_b
nMSetOut_a
CTRL
Abb. 2−1 Holding brake (L_BRK)
VariableName
DataType SignalType VariableType Note
bSet_b Bool binary VAR_INPUT
nNx_a Integer analog VAR_INPUT Speed threshold from which the drive can output the
signal "close brake". The signal source for this input
can be a control code, a fixed value or any other
analog output of a FB.
nSign_a Integer analog VAR_INPUT Direction of the torque which the drive has to build up
against the brake. The signal source for this input can
be a control code, a fixed value or any other analog
output of a FB.
bQSP_b Bool binary VAR_OUTPUT QSP can be triggered in conjunction with MCTRL.
bOut_b Bool binary VAR_OUTPUT Set the brake
bMStore_b Bool binary VAR_OUTPUT provide a defined holding torque
bCInh_b Bool binary VAR_OUTPUT A controller inhibit can be set in conjunction with
DCTRL.
nMSetOut_a Integer analog VAR_OUTPUT Holding torque of the DC injection brake
16384 = value of C0057 (max. possible torque for the
drive configuration)
wReleaseTime Word VAR CONSTANT RETAIN Brake disengaging time
wActivationTime Word VAR CONSTANT RETAIN Brake engaging time
nMSet Integer VAR CONSTANT RETAIN Holding torque
DCTRL_bCInh_b Bool
These signals are processed as quantities within the
FB.
MCTRL_nNAct_a Integer
MCTRL_nNSet2_a Integer
MCTRL_nMAct_a Integer
Parameter codes of the instances
VariableName L_BRK1 SettingRange Lenze
wReleaseTime C0196 0.0 ... 60.0 s 0.0
wActivationTime C0195 0.0 ... 99.9 s 99.9
nMSet C0244 −199.99 ... 199.99 % 0.00
Vue de la page 10